Ordering details | |
---|---|
Product type description | Z4K 256 STL-AS 2S - Ordering suffix |
Article number | Z4K 256 STL-AS 2S |
EAN Code | |
eCl@ss | 27-27-26-01 |
Approval | |
Approval | |
Classification | |
Application: Two position switches, dependent, on one safety guard: | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up e |
Control category | up 4 |
PFH | 2 x 10−8 / |
- notice | up to max. 100000 switching cycles/year |
SIL | up 3 |
Mission time | 20 Years |
Application: Each time one position switch, independent, on two safety guards: | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up c |
Control category | up 1 |
PFH value | 1.14 x 10−6 / |
- notice | up to max. 100000 switching cycles/year |
SIL | up 1 |
Mission time | 20 Years |
Global Properties | |
Permanent light | AS - 256 2S Winkelhebel 4K |
Standards | EN 50295, EN 60947-5-1, EN ISO 13849-1, IEC 61508 |
Compliance with the Directives (Y/N) | Yes |
Suitable for safety functions (Y/N) | Yes |
Materials | |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the connector | Plastic |
- Material of the contacts | Silver |
Housing coating | |
Housing construction form | Norm construction design |
Weight | |
Mechanical data | |
Design of electrical connection | connector plug M12, 4-pole (AS-i connection) connector socket M12, 4-pole (2. switch) |
connector | left () right (2. switch) |
Mechanical life | 1.000.000 operations |
Switching frequency | 5000 |
Design of actuating element | Angle roller lever |
Actuating force | 6 |
restistance to shock | 30 / 11 |
Resistance to vibration | 10 … 150, Amplitude 0,35 / 5 |
Positive break force | 16 |
Actuating speed for vertical actuation | |
- Max. Actuating speed | 1 |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30 … 95 |
- non-condensing | |
- non-icing | |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | II |
<img class="noprint nodialog" src="https://w</strong> |